Ref. No. : CA - 34091 - (Maintenance and Service - Electrical – with 20.6 years in Plastic Industry)

Education

Bachelor of Electrical Engineering, 2004
Shri SankalchandPatel College of Engg ,Visnagar ,Hemchandracharya NorthGuj University Patanwith 67.2%.
Diploma in ElectricalEngineering, 2000
R.C.TechInst A bad, Tech exam boardGujaratstate with 68.6%.

Skill Sets

Computer Skills
SAP,MSOffice, excel, power point, andInternet Applications.

Work Experience

E & I Engineer.
From - Jan-2020 To Dec - 2021.
Company profile - Manufacturer of luxury glass bottles for perfumes and cosmetics

Maintenance Engineer.
From - Oct-2018 To Aug 2019
Company profile - Medical Institute & Research

Lab Asst/Lecturer.
FEB-2018 TO OCT 2018.
M/S I.T.MVOCATIONAL UNI.

Electrical Engineer.
AUG-2016 TO JAN-2017
M/S AARVI ENCON PVT LTD.

Lab Asst/Lecturer.
AUG-2015 TO JULY 2016
M/S I.T.MVOCATIONAL UNI

Electrical testing Engineer
JAN-2015 TO APR-2015
M/SQ.CON (QATAR)

Electrical Engineer.
AUG-2014 TO DEC 2014
M/S AARVI ENCON PVT LTD

E & I Engineer
DEC-2012 TO JUL-2014.
M/SSAVER GLASS LLC (UAE)

Sub-station & Switch Yard:
Testing, commissioning, preventive maintenance, conditional monitoring, operation and trouble shooting of the following
electrical equipment.
Transformer& OLTC: - 66/6.6/11/0.415KV up to 10MVArating.
HT& LT breakers:- SF6/Vaccum/Air circuit breaker up to66kv.
Make: - ABB, Schneider, L&T and Siemens.
HT & LT feeders: - PCC, PMCC, MCC, LDB etc.
Make: - Siemens, L&T etc.
Protection Relays:-E/F andO/C,Differential,Over voltage, under voltageetc.
Make: - ABB, Siemens and Sepametc.
UPS & Battery charger: - Single and three phase ups up to 60 kVA.
Battery charger rated 48/24 volts DC.
Capacitor bank: - For power factor correction rating up to 50 KVAR. And in multiple ofit.
CAPTIVE POWER PLANT & UTILITIES:
Operation, preventive maintenance,conditional monitoring,and trouble shooting of below equipment.
Gas Generator: - 6MW *4 , 11 KV.
Make: - Vertsila, GE etc.
Auxiliarys:- Cooling tower, Plate heat exchanger, Circulating Pumps,Oil pre-heatersetc.
Control& Synchronizingpanels:-Operation& troubleshooting.
ProtectionRelays:-E/FandO/C, Differential,Over voltage, under voltage etc.
Make: - VAMP.
Compressor:- Atlas copcoZR &ZHseries.
R.Oplant:- OVIVOmake automatic reverse osmosis plant.
HVAC System:- Chiller A.C, Split A.C , Window A.C & Dryers.
AUTOMATION:
Operation, preventive maintenance, conditional monitoring,and trouble shooting below equipment.
Variable frequencydrive:- AC drives up to 200KWrating.
Make:- ABB, Siemens etc.
PLC& DCS:- Analog& Digital Input/Output, AtoD and D to Aconverter etc.
Make- Siemens etc.
Instrumentation:- PT100, Thermocouple, Proximity sensors and PID Controllers, Pyrometers, valves etc.
GENERAL ELECTRICAL EQUIPMENTS & TESTING:
Testing,Operation,preventive maintenance, conditional monitoring, and trouble shooting of below equipment.
Motors & Starters:- A.C single & three phase motors and starters up to rating 1 MW, 6.6 KV.
Hoist crane:- up to 2 ton capacity.
Testing:- Hi-potential testing of cables, transformer and bus bars etc.
Insulation resistance testof Cables,motors, transformers etc.
Impedance test of batteries.
Earth pitresistance test.
ENV, HEALTH, SAFETY & QUALITY MGMT:
Fire detectors and fire fighting equipments.
Plantfire hydrantsystem.
ISOdocumentation.

Copyright © 2003 - 2015 Smartech Global Solutions Ltd. All rights reserved. Designed by Plastemart.com