B.E Mechanical from Raja Rajeswari Engineering College, Chennai with 72% in May 2005.
HSC from N.S.Higher secondary School, Theni District Passed with 86% in March 2001.
SSLC from N.S.Higher secondary School, Theni District Passed with 84% in March 1999.
Designation: Assembly Engineer.
Duration: April 2008 to till date.
Presently working with a leading company
Description:
Manufacturing of special purpose machines like Twin Ram vertical turning lathe, Traveling column Horizontal Machining Center, Water Jet Machine etc.,
Contribution:
Involved in assembly of Twin ram VTL.
Involved in Main assembly.
Involved in Gear box assembly
Co-ordinating the activities among the group members.
Designation: Execution Engineer.
Duration: April 2007 to March 2008.
Name of the Organization: Avasarala Technologies Limited, Bangalore.
Company Profile:
The Avasarala groups has various organization like
(a)Avasarala Technologies Ltd, (b) Avasarala Tungsten Ltd, (c) Elbeam Devices Ltd.,
The group principle activities involved in various Turnkey projects consultancy and implementation, Nuclear power projects, Design and fabrication of special purpose machineries. The group also having collaboration with M/s flex Link Corporation for the manufacture of plastic chain conveyor systems.
I had worked for R.S. Engineering (sub contract of Avasarala Technologies Limited)
I have been deputed to RAJASTHAN ATOMIC POWER PROJECT # 6.
Description:
Coolant channel replacement
The key advantage of this project is to increase power production and to fulfill the peoples needs. Here the power produced is of 235MW. Since its a new plant calendria vessel has to be measured. Process carried out are platform erection, calendria tube trimming followed by calendria tube installation and rolling.
Contribution:
Involved in measurement of calendria vessel.
Involved in pre-assembly area were liner tube is rolled with end fitting.
Rectified carriage marks, nail feel able scratches, etc.
To identify the areas where further information is required on pre assembly.
Involved in pressure tube trimming area.
Designation: Execution Engineer.
Duration: May 2006 to March 2007.
I have been deputed to NARORA ATOMIC POWER STATION.
Description:
Enmass coolant channel replacement
The main objective of this project is to increase power production. It is actually a replacement of an existing project. It is the first project in India, in which replacement had carried out were bellow had been installed. Here the power produced is of 235MW. Operations performed are platform erection, zigzag panel removal, feeder cutting, gray loc removal, bellow lip cutting, end fitting & pressure tube cutting and removal.
Later carried out by degreasing of end fitting and reactor component, shrink fitting of bellow attachment cast steel ring, pre-assembly of reactor component, pressure tube trimming, one end rolling, south vault installation, north vault installation and rolling, bellow welding, feeder welding, shield plug & seal plug installation at one end, fuel loading, shield plug & seal plug installation at other end, gray loc clamping and commissioning the plant.
Contribution:
Involved in pre-assembly area were liner tube is rolled with end fitting.
Involved in this project as an Execution Engineer.
Co-ordinating the activities among the group members.
Identified and rectified problems like scratches, dent mark, pitting, etc.
Involved in creation of documentation in this project.
Leaded the team, organizing in vault activities.
Designation: Execution Engineer.
Duration: Sep 2005 to April 2006.
I have been deputed to RAJASTHAN ATOMIC POWER PROJECT # 5.
Description:
Coolant channel replacement
The key advantage of this project is to increase power production and to fulfill the peoples needs. Here the power produced is of 235MW. Since its a new plant calendria vessel has to be measured. Process carried out are platform erection, calendria tube trimming followed by calendria tube installation and rolling.
Then proceeded with bellow installation and rolling, degreasing of end fitting and reactor component, shrink fitting of bellow attachment cast steel ring, pre-assembly of reactor component, pressure tube trimming, one end rolling, south vault installation, north vault installation and rolling, bellow welding, fuel machine erection, feeder welding, shield plug & seal plug installation at one end, fuel loading, shield plug & seal plug installation at other end, gray loc clamping and commissioning the plant.
Contribution:
Involved in measurement of calendria vessel.
Involved in pre-assembly area were liner tube is rolled with end fitti
To be sincere and work with an organization that provides an opportunity to grow, learn and exploit my potential to excel in the area of my purview so as to help the organization in accomplishments of its goals.