Diploma (Electrical Engineer) from Government Polytechnic Rajkot, Technical Education Board, Gandhinagar. with 65.43 % in DEC-2006.
HSC from V.S.Patel Highschool Kosamba in Gujarat Secondary & Higher Secondary Education board with 41.00 % in 2004.
SSC from V.S.Patel Highschool Kosamba in Gujarat Secondary & Higher Secondary Education board with 78.43 % in 2001.
SAP
Microsoft Outlook
MS-Office
Basics of Auto cad
Senior Engineer.
From - 03st Mar - 2008 to Till Date.
Company profile -Manufacturing glass bottles based
job profile -
My work profile covers Electrical Plant Maintenance/Trouble Shooting & CPP Operation & Maintenance
Agency Electrical Engineer
From -26th June - 2007 to 29th Feb 2008
Company profile - Global leadership in the core energy and materials value chain
Job profile -
Preventive Maintenance of Electrical Equipments such as Motors, PCC Panels, MCC Panels, Transformers, Circuit Breakers, Insecticutors, Water Pumps, HVAC system chillers, etc.
Handling normal & emergency maintenance activities as per company SOP & performance monitoring of machines.
Preparing SOP for Plant load changeover for Power Shutdowns/Breakdowns.
Condition Monitoring of all Electrical Equipments.
Doing Yearly Preventive Maintenance of Transformers, LT ACB, HT CB, Earthing Pits,
HT Switch Yard & DG Sets as per PM schedule.
Prepare yearly, half yearly, quarterly & monthly maintenance schedule for motors and other electrical equipments.
Maintaining electrical safety of different electrical equipments.
Preparing Electricity self-duty reports of Engine Sets, ISO audit reports.
Making monthly report of Energy Statement.
Maintaining Inventory for Electrical materials as per requirement.
Maintaining Department Tools & Equipments as per 5S Strategy.
Operation & Maintenance of 1.0 MVA, 2.0 MVA, 2.5 MVA, 4 MVA & 15 KVA Transformer
Operation & Maintenance of Indoor VCB, 1250 amp, 22 KV (L&T & Siemens make HT)
Operation of ACB 3200 amp, 2000 amp, 1600 amp, 1000 amp, 800 amp (L&T make LT)
Variable Frequency Drives operation from 20HP to 50HP ( ABB & Siemens make)
Operation & Maintenance of 415/0-470 V, 1600 amp variacs (Voltamp make)
Operation & Maintenance of UPS System.
Restore power during BLACKOUT/Power Failure & Make plant stable to full load.
Operation & maintenance of 3.3 MW captive power plant which consist of
J420GSB11 Jen Bacher Gas Engine 1x1.5 MW (11K running hours achieved)
J320GSC05 Jen Bacher Gas Engine 1x1.06 MW (59K running hour achieved)
J316GSC05 Jen Bacher Gas Engine 1x0.83 MW (35K running hour achieved)
Operation & Maintenance of 500KVA x 2, 625KVA x 2, 750KVA x 1 & 1500 KVA x 2 DG Sets.
Execution of major & minor shutdown within the time limit.
Copyright © 2003 - 2015 Smartech Global Solutions Ltd. All rights reserved. Designed by Plastemart.com